Problem Addressed

Many peopleÌýsuffer fromÌýpoorÌýindoor airÌýquality (IAQ)ÌýleadingÌýtoÌýhealth problemsÌýfor the individualÌýand high costs (sick leave, medicalÌýcosts)ÌýforÌýwiderÌýsociety.ÌýAwareness ofÌýthe importance ofÌýIAQÌýandÌýrelated symptomsÌýis on the rise in the UK,Ìýwhere the incidence of asthma is among the highest in the world.ÌýÌý

ÌýAÌýcommonÌýcause of poor IAQ isÌýthe spread ofÌýchemical and/or biological agents from the buildingÌýitselfÌýinto the indoor air.ÌýThe problemÌýis often, but not always,Ìýdue toÌýbuilding moisture.ÌýHow can we address symptomsÌýof building related illnesses (BRI)Ìýsuch as asthma, skin and eye irritation, fatigue, concentration difficulties?

Solution Overview

TheÌýcTrapÌý(surface emissions trap)Ìýcloth is a functional fabricÌýthatÌýimproves theÌýindoor air quality (IAQ) by capturing and binding harmful airborne chemicals that areÌýspread from the buildingÌýinto the indoor air.ÌýThe problem is particularly pronounced in damp buildings.ÌýcTrap is a four-layer laminate in the form of a cloth, delivered on a roll. The cloth is attached indoors on walls, floors and/or ceilings, depending on where emissions are originating. A flooring of choice can then be laid over the cTrap cloth or, when the emissions are coming from the wall or ceiling, a thin plasterboard. With fast installation and directÌýeffect,ÌýcTrap ensures a clean and healthy indoor environment, without using chemicals or consuming energy. Ìý

cTrapÌýis a laminate of two functional layers – one adsorbent layer and one layer of a hydrophilic polymer – plus one inner and one outer protective layer.ÌýItÌýisÌýair tightÌýandÌýstops and adsorbs all emissions,Ìýincluding volatile organic compounds (VOC), that areÌýbeing spread from the surface to whichÌýthe clothÌýis being attached. At the same time,Ìýthe clothÌýallowsÌýwater vapour to pass through with almost no resistance at all. TheÌýcTrapÌýthus does not affect the moisture balance of the building, andÌýthere is no risk of water condensation which might lead to mould growth. TheÌýclothÌýcan be attached on any surface.ÌýÌý

The productÌýcontains no chemicals,Ìýand no chemicals are used during installation. Furthermore, theÌýcTrapÌýworks without consuming energyÌýandÌýstops and binds emissionsÌýirreversibly.ÌýThe manufacturing processÌýalso bears environmental impact in mind, usingÌýexclusivelyÌýrenewable and recycled products.ÌýcTrapÌýis a result of Prof Lennart Larsson’s research at Lund University, Sweden,Ìýand there is a wealth of scientific documentationÌýas concerns adsorption efficiency, water vapour resistance, air tightness etc.Ìý

cTrapÌýis a unique product whichÌýsolves IAQ problems whichÌýareÌýdue to spread of chemical and/or biological emissions from the building itself into the indoor air. ÌýItÌýis a unique productÌýdevelopedÌýfrom a PhD project at Lund University Sweden. cTrapÌýis patentedÌýin the UK, most EU countries, North America, and China.ÌýÌý

Case Study

Example case studies:ÌýÌý

  • AÌýwooden houseÌýwith a “summer cottageâ€� mould-likeÌýsmell indoors. The building had previously been treated with preservativesÌýthat, underÌýmoist conditions,ÌýformÌýhighly odorousÌýchloroanisoles.ÌýThe ceiling, walls and floor in the bedroom, but notÌýliving-room,Ìýwere covered withÌýcTrap.ÌýTetrachlorophenol,Ìýtrichloroanisole, andÌýpentachloroanisoleÌýwere detected in the air of the living-room,Ìýbut onlyÌýtetrachlorophenolÌýwas found in the bedroom,ÌýandÌýin a concentration 93% lower than in the living room.ÌýThe mouldy odour disappearedÌýimmediatelyÌýfollowing theÌýcTrapÌýinstallation.ÌýÌý
  • A building where a tar layer had been attached ontoÌýaconcreteÌýslab,ÌýasÌýmoisture barrier. The air concentrations of polycyclic aromatic hydrocarbons (PAH) wereÌý1726 ng/m3. TheÌýdisturbing smell inside the buildingÌýpersisted even after the tar had been removed. TheÌýcTrapÌýcloth was installed on about 75 percent of the wall surface, the smell disappeared,Ìýand theÌýPAHÌýÌýconcentrationÌýdecreased to 139 ng/m3,Ìýa reduction of 92%.Ìý
  • AÌýtownhouse where the tenants suffered fromÌýitching and headachesÌýwhen at home. A PVC flooring had been glued ontoÌýtheÌýconcrete slab which had become moist through diffusion of water from the ground. The air concentration of 2-ethylhexanol, a compoundÌýformedÌýbyÌýhydrolysis of glue and/or phthalates, was 63 µg/m3.ÌýcTrapÌýwas attached onto the existing flooring,Ìýthe air concentrations of 2-ethylhexanol decreased toÌý1.5 µg /m3, and the symptoms disappeared.ÌýThe same low valueÌýwas found in a follow-up study 6 yearsÌýlaterÌý– and theÌýtenantsÌýstill reported no symptoms.Ìý

This page presents data, evidence, and solutions that are provided by our partners and members and should therefore not be attributed to UKGBC. While we showcase these solutions for inspiration, to build consensus, and create momentum for climate action, UKGBC does not offer commercial endorsement of individual solutions. If you would like to quote something from this page, or more information, please contact our Communications team at media@ukgbc.org.